“A nice example showing how Motion Amplification can be used on many different types of faults. The client was experiencing multiple bearing and seal failures. Standard VA showed slightly raised 1XRPM of 3.5mm/sec RMS in axial and radial directions. The IRIS M 2.3 million pixel sensors show the motion beautifully. This led to an investigation which found the bearing housing had been machined incorrectly after an overhaul 14 months previously.” — Stuart Walker